N2XS(FL)H  6/10 (12)kV Cable
+
  • N2XS(FL)H  6/10 (12)kV Cable

N2XS(FL)H 6/10 (12)kV Cable

Application:Designed for installations where fire safety and moisture protection are important. Suitable for medium-voltage power distribution (6/10 kV systems),utility distribution networks,industrial plants and factories,commercial buildings,power stations and substations,renewable energy projects (solar farms and wind farms),data centers,underground cable installations,cable ducts and conduits,outdoor installations where UV resistance is required

WhatsApp:

Description


  • 产品描述
  • Application:Designed for installations where fire safety and moisture protection are important. Suitable for medium-voltage power distribution (6/10 kV systems),utility distribution networks,industrial plants and factories,commercial buildings,power stations and substations,renewable energy projects (solar farms and wind farms),data centers,underground cable installations,cable ducts and conduits,outdoor installations where UV resistance is required

    CHARACTERISTICS

    Voltage Rating Uo/U (Um)

    6/10 (12)kV

    Temperature Rating

    -20°C to +90°C

    Minimum Bending Radius 

    15 x overall diameter

    CONSTRUCTION

    Conductor 

    Class 2 Stranded Copper

    Conductor Screen

    Semi-conductive material

    Insulation

    XLPE (Cross-Linked Polyethylene)

    Insulation Screen

    Semi-conductive material (bonded)

    Longitudinal Waterblocking

    Semi-conductive swellable tape

    Screen

    Copper wires and copper tape

    Longitudinal Waterblocking

    Swellable Tapes

    Radial Waterblocking

    Al/PET (Aluminium/Polyester) tape tightly bonded to sheath

    Outer Sheath 

    LSZH (Low Smoke Zero Halogen)

    STANDARDS

    IEC 60502-2, IEC 60228,

    Low Smoke Zero Halogen: IEC 60754-1/2, IEC 61034-2 

    Flame Retardant: EN 60332-3-24 Cat C, IEC 60332-1-2 

    UV Resistant: EN 50396

    Abrasion and Tear Resistant: EN 60229-4.1

    Impact rated to: AG2 EN 60364

    NO. OF CORESNOMINAL CROSS SECTIONAL AREA mm2NOMINAL OUTER DIAMETER OF CABLE mmNOMINAL WEIGHT kg/km
    CONDUCTORCOPPER WIRE SCREEN
    1501623.5995
    17016251235
    19516271440
    112016391740
    11502530.52050
    118525322550
    12402534.53080
    13002536.53820
    14003539.54575
    150035445825

FAQs


Do your cables comply with IEC international standards?

Yes. Our cables are manufactured with reference to IEC international standards, and the corresponding EN European standards and GB/T Chinese national standards are available, such as IEC 60228, IEC 60502-1, IEC 60332, IEC 60754 and IEC 61034. We can supply the full IEC-EN-GB/T mapping table for your tender review and technical evaluation.

Are your type-test reports ILAC-recognized for international tender projects?

All our type-test reports are issued according to ILAC-recognized standards, which meet the requirements of IAF multilateral agreements. For the specific rules of the destination country and the specifications of the tender authority, the required documentation can be discussed and confirmed separately.

What main cable types can Youhui Cable supply?

Our product range covers HV/MV/LV XLPE power cables, flame-retardant and fire-resistant cables, pre-assembled branch cables, control cables, aerial insulated cables, compensating cables, building wires, low-smoke halogen-free (LSZH) cables and other special-purpose industrial cables. Customized solutions are available for specific project conditions.

What certifications does Youhui Cable hold?

We hold ISO 9001 quality management system certification. We also hold the China Compulsory Certification (CCC) and the Mining Products Safety Mark (MA) for applicable products. Additional documents required for your project can be coordinated upon request.

Can you produce custom-built cables for special industrial or infrastructure projects?

Yes. We continuously invest in R&D. We can adjust conductor size, insulation and sheath material, flame-retardant grade and structure according to your working conditions and tender specifications. Corresponding test documentation will be provided for customized orders.

What is your production capacity and factory scale?

Founded in 2007, our plant covers 180,000 m² including 60,000 m² of production area, equipped with 40 specialized production lines. Our annual production capacity exceeds RMB 1 billion, supporting both large-volume standard orders and custom-specification batches.

N2XS(FL)H 6/10 (12)kV Cable

Application:Designed for installations where fire safety and moisture protection are important. Suitable for medium-voltage power distribution (6/10 kV systems),utility distribution networks,industrial plants and factories,commercial buildings,power stations and substations,renewable energy projects (solar farms and wind farms),data centers,underground cable installations,cable ducts and conduits,outdoor installations where UV resistance is required

WhatsApp:


OUR SERVICE

We offers a wealth of product support resources, including a range of technical and downloadable product manuals to product certifications.

Contact Us

Request a Quote

Complete the inquiry form with your detailed demands. Our experienced team will provide tailored quotation and technical support for you.

SUBMIT

Get Your Custom Quotation

Tell us your scenario and requirement — our team replies within 24h.

Send Request
%{tishi_zhanwei}%